KEMPEROL 2K-PUR is a two-component, UV-stable high performance seamless and self-terminating cold fluid-applied polyester reinforced solvent-free. KEMPEROL 2K-PUR Speedshot combined with KEMPEROL 2K-PUR is the ideal solution for all applications where speed is essential. These include balconies. KEMPEROL® 2K-PUR is a solvent-free and odourless, fully reinforced, polyurethane resin-based liquid waterproofing system. It is ideal for use on sustainablility.

Author: Mikinos Vozshura
Country: Singapore
Language: English (Spanish)
Genre: Business
Published (Last): 6 July 2009
Pages: 493
PDF File Size: 9.53 Mb
ePub File Size: 9.20 Mb
ISBN: 490-1-90049-896-6
Downloads: 77910
Price: Free* [*Free Regsitration Required]
Uploader: Gardaramar

Flashing is typically constructed as a two part assembly consisting of a vertical wrap and a horizontal target patch. Fit plywood to all penetrations, projections, and nailers.

Metal flashings shall be fabricated in accordance with the current recommendations of Kempsrol and in accordance with the Manufacturer’s standard drawings. Follow manufacturer’s directions for protection of materials prior to and during installation. Each product clause is authored in NBS format and is intended for inclusion in project specifications.

Additive specifically designed to accelerate the resin reaction time at ambient temperatures below 50 degrees F 10 degrees C. Do not apply primer on any substrate containing asphalt, coal-tar pitch, creosote or penta-based materials unless approved in writing by Membrane Manufacturer. Provide continuous cleaning with water and brush to eliminate settlement of concrete residues on in-place waterproofing membrane adjacent to area of concrete placement.

Hunter Panels-Tapered H-Shield, 1. Place drainage mat fabric side up on top of finished waterproofing membrane. Determine the locations kempeol the horizontal surfacing profile joints and mark off with 2l line. Install only as much insulation and cover board as can be primed, sealed, and protected before the end of the day’s work or before the onset of inclement weather. Delete if not applicable.

Do not use kkemperol flashing cement. Company specializing in performing the work of this section with a minimum of 3 years documented experience and approved by system manufacturer for warranted membrane installation.

  BGI 5021 PDF

KEMPEROL┬« 2K-PUR Liquid Applied Solvent-Free and Odourless Waterproofing – Cold Roof System

Such warranties generally ensure a more vested interest in the integrity of the installation. Where results exceed the maximum acceptable reading contact Membrane Manufacturer for recommendations. Concrete shall be abrasively cleaned in accordance with ASTM D to provide a sound substrate free from laitance.

Any incidents of water entry shall be evaluated and all necessary repairs conducted, followed by an additional flood test. Polyisocyanurate Insulation Cover Board: To be applied between hours after application at 73 degrees F, 50 percent relative humidity.

SECTION 07 14 16 COLD FLUID APPLIED (KEMPEROL 2K-PUR) WATERPROOFING

Kemper System Canada, Inc. Store materials off the ground or on pallets, under cover pir in a cool, dry location, out of direct sunlight, in accordance with manufacturer’ s recommendations. Wood nailers are required to match the thickness of insulation and cover board, and are to be secured directly to the structural deck. Kemperol 2K-PUR kemmperol only be applied by specially trained applicators. If the ambient temperature is below 50 degrees F 10 degrees Cthen a weather related additive should be combined and mixed into the Component A.

Kemper System products provide the best peace-of-mind solutions for a lifetime of protection for your most valuable assets, applications include: It is designed for use as an adhesive for bonding approved roof insulation and cover board to kkemperol building’s structural roof deck, base sheets, and smooth or properly prepared graveled built-up roof surfaces.

Install mineral-surfaced cap sheet in accordance with cap sheet manufacturer’s current published specifications and recommendations for use with adhered waterproofing.

Kemperol 2K-PUR – Kemper System Ltd

Sensitive areas such as schools, public places and food manufacturing plants, Applications that favour the use of the most environmentally friendly kemerol, Floors of boiler, control and plant rooms, Complex detailing, Roofs, Balconies, Terraces, Podiums, Fountains and Gutters.

As a minimum provide one fastener and plate per 2 square feet of insulation and cover board to be attached with: Your browser does not support automatic copy to clipboard.

  GOJO MSDS PDF

Create openings in the drainage core to correspond with all discharge holes in the drain at the structural deck level. It is particularly suitable for use on occupied buildings that would be sensitive to a solvent-based application, such as schools, hospitals or food factories, allowing remedial work to take place without the need for evacuation or closure.

Mixing Proportions ekmperol be a ratio of resin to sand at 1: Smaller areas shall receive a minimum of 3 tests.

Other content by this manufacturer: Do not allow waste products containing petroleum, grease, acid, solvents, vegetable or mineral oil, animal oil, animal fat, etc.

Kemperol 2K-PUR highly permeable roofing membrane

Roofdrain green roof drainage and water storage layer Lindum Turf. Provide a minimum vertical height of 8 inches for all flashing terminations. Seal filters at joints and against building kwmperol walls to prevent leakage of unfiltered air. If any unmixed resin contacts membrane surface remove immediately and clean thoroughly with a cloth rag. Non-woven polyester fabric, minimum 4.

Neatly fit insulation to all penetrations and projections. Mechanically fasten wood nailers as required to resist a force of lbs per lineal foot, but with no less than 5 fasteners per 8 foot or 6 fasteners per 10 foot length of nailer.

Fabric must be left intact at these holes to prevent intrusion of soil, grout, sand, or concrete into the drainage core. Edges shall be checked so that no edges are left kempedol unsupported along the flutes. Pour primer Component B into Component A and mix for approximately 2 minutes with a clean spiral agitator on slow speed without creating any bubbles or streaks.

Butt one panel edge to edge of adjacent panel. Blistering of membrane may result from excessive substrate moisture.